icon

RECIPE

Detection of Intrusion into Hazardous Areas

POINT
This recipe uses intrusion detection sensors installed in hazardous areas to notify management of any intrusion.

This recipe is ideal for problems such as:

Conventional supervision of hazardous areas

Workers used to mistakenly intrude into designated hazardous areas in the plant, which could result in serious accidents and errors in the production facilities, therefore, we needed staff to patrol the areas.

It is impossible for site supervisors to supervise everywhere and every time.

icon

Three Simple Steps to Introduction

Anyone can start using amnimo sense recipes quickly and easily.

STEP1 Purchase
icon
STEP2 Installation
icon
STEP3 Start
icon

By introducing the Recipe for Detection of Intrusion into Hazardous Areas, it is possible to:

icon

Eliminate the necessity of walk-around checks of the surrounding hazardous areas.

PCimage

icon

Save and store the vast quantities of data generated on a daily basis.

PCimage

Enables thoroughly even supervision where site supervisor cannot monitor and allows for quick decision-making and responses to ensure workers'safety.

PCimage

Reduction in personnel expenses

PCimage

Improved safety

amnimo sense Recipe for Detection of Intrusion into Hazardous Areas

–Schematic Diagram–

  • Real-time visualization
  • Accident prevention
  • Cost reduction

amnimo sense can be installed to suit any equipment environment.Combine amnimo sense with commercially available parts for easy installation.

image

Data is sent from the sensor installed in the entrance to hazardous areas and end-point devices.

arrow

LoRa arrow

image

Install sensors into no-entry one.

image

LTE arrow

image

Record and store whether there were any intrusions in the database.

arrow

image

Customers can see any intrusion on their computers and smartphones.

  • Please note that amnimo does not guarantee correct operation of amnimo sense in your environment.
    Please configure and use amnimo sense under your own responsibility.
  • The recipes developed as of May 2019 use LoRa endpoint devices with analog input.
  • The recipe should be regarded strictly as a sample case only. amnimo does not guarantee that it will solve your business issues.
  • The devices listed are produced by various manufacturers and are subject to discontinuation by the manufacturers at any time. amnimo does not guarantee the availability of the models listed.
  • Amnimo accepts no responsibility for incorrect operation of the recipe as configured by the customer, except where caused by a service error of amnimo.
  • If the recipe fails to operate as configured using equipment selected by the customer, amnimo offers no guarantee against, and accepts no responsibility for, incorrect operation.
  • Amnimo accepts no responsibility for cases in which cost, including the equipment listed in the recipe and amnimo's services, is higher than the customer anticipated.
  • Inquiries regarding recipe customization are not accepted by Amnimo.

Endpoint device

  • picture1

Gateway

  • picture1
You will need
  • One amnimo sense set(endpoint devices, gateway, communications, dashboard)

Subscribe amnimo sense
from our e-commerce site
*You can subscribe amnimo sense after account registration.
Please contact us for account registration.

Optional item
For 10 endpoint devices (measurement points)

  • Batteries (N alkali batteries) × 30(Or USB cable (Type C) × 1- + USB charging adapter × 10)
  • Wiring for connections × 30
    Recommended product
  • 12V AC adapter × 20
    Recommended product
  • Between standard 2.1mm DC jack and small screw terminal board × 20
    Recommended product
  • Monopole terminal board × 30
    Recommended product
  • Resistance of 3.6k Ohm × 10
    Recommended product
  • Resistance of 5.1k Ohm × 10
    Recommended product
  • Area sensor × 10
    Recommended product
  • Endpoint storage case
    Recommended product
  • Cable glands
    Recommended product

iconThe amnimo sense set does not include sensors or parts. Please note that the companies that supply the sensors and parts used in this recipe cannot respond to inquiries regarding this recipe.

Procedure for using amnimo sense

Guide for procedures to implement recipes.

  1. You can subscribe amnimo sense after account registration.
    Please contact us for account registration.

  2. Gateways are activated first, followed by endpoint devices.

    picture2

  3. Sensors, gateways and endpoint devices are wired up.

    picture3

  4. Power is supplied to the endpoint devices to start up the system.

    picture4

  5. Widget settings are established to display the data.

    picture5

In addition to plant, this recipe can be used in the following environments.

SCHOOL

Schools

This recipe is ideal for situations such as construction sites, where workers have difficulty establishing site patrols after they have left the site at night or in inclement weather.

FACTORY

Construction

This recipe is ideal for situations such as construction sites, where workers have difficulty establishing site patrols after they have left the site at night or in inclement weather.