icon

RECIPE

CO2 Concentration Management for Greenhouse Cultivation

POINT
This recipe easily measures and manages CO2 concentrations and temperatures, which have a large impact on plant growth.

This recipe is ideal for problems such as:

Conventional greenhouse cultivation

In many cases in greenhouse cultivation, the CO2 generator runs at a predefined starting time for a certain period of time, and it is difficult to obtain the actual CO2 concentration.

Manually checked on a regular basis…

icon

Three Simple Steps to Introduction

Anyone can start using amnimo sense recipes quickly and easily.

STEP1 Purchase
icon
STEP2 Installation
icon
STEP3 Start
icon

By introducing the Recipe for CO2 Concentration Management for Greenhouse Cultivation, it is possible to:

icon

Maintain the best CO2 concentration levels with the CO2 controller.

PCimage

icon

Obtain CO2 concentration levels at any time from home.

PCimage

icon

Save and store the vast quantities of data generated on a daily basis.

PCimage

Eliminates the time and effort to manage inside greenhouse, reduces costs, and increases crop yields.

PCimage

Reduced losses

PCimage

Reduction in personnel expenses

PCimage

Improved productivity

amnimo sense Recipe for CO2 Concentration Management for Greenhouse Cultivation

–Schematic Diagram–

  • Real-time visualization
  • Storage of the vast quantities of data generated daily
  • Cost reduction
  • Improved productivity

amnimo sense can be installed to suit any equipment environment.Combine amnimo sense with commercially available parts for easy installation.

image

Data is sent from the CO2 controller installed inside the greenhouse and end-point devices.

arrow

LoRa arrow

image

Install inside the customer’s greenhouse.

arrow

image

image

LTE arrow

image

Past CO2 concentration levels are recorded, stored, and managed in a database.

arrow

image

The customer can confirm inventory levels from a PC or smartphone.

  • Please note that amnimo does not guarantee correct operation of amnimo sense in your environment.
    Please configure and use amnimo sense under your own responsibility.
  • The recipes developed as of May 2019 use LoRa endpoint devices with analog input.
  • The recipe should be regarded strictly as a sample case only. amnimo does not guarantee that it will solve your business issues.
  • The devices listed are produced by various manufacturers and are subject to discontinuation by the manufacturers at any time. amnimo does not guarantee the availability of the models listed.
  • Amnimo accepts no responsibility for incorrect operation of the recipe as configured by the customer, except where caused by a service error of amnimo.
  • If the recipe fails to operate as configured using equipment selected by the customer, amnimo offers no guarantee against, and accepts no responsibility for, incorrect operation.
  • Amnimo accepts no responsibility for cases in which cost, including the equipment listed in the recipe and amnimo's services, is higher than the customer anticipated.
  • Inquiries regarding recipe customization are not accepted by Amnimo.

Endpoint device

  • picture1

Gateway

  • picture1
You will need
  • One amnimo sense set(endpoint devices, gateway, communications, dashboard)

Subscribe amnimo sense
from our e-commerce site
*You can subscribe amnimo sense after account registration.
Please contact us for account registration.

Optional item
For 10 endpoint devices (measurement points)

  • Batteries (N alkali batteries) × 30(Or USB cable (Type C) × 1- + USB charging adapter × 10)
  • Wiring for connections × 20
    Recommended product
  • Dipole terminal board × 10
    Recommended product
  • Resistance of 250 Ohm × 10
    Recommended product
  • CO2 sensor × 10
    Recommended product
  • Endpoint storage case
    Recommended product
  • Cable glands
    Recommended product

iconThe amnimo sense set does not include sensors or parts. Please note that the companies that supply the sensors and parts used in this recipe cannot respond to inquiries regarding this recipe.

Procedure for using amnimo sense

Guide for procedures to implement recipes.

  1. You can subscribe amnimo sense after account registration.
    Please contact us for account registration.

  2. Gateways are activated first, followed by endpoint devices.

    picture2

  3. Sensors, gateways and endpoint devices are wired up.

    picture3

  4. Power is supplied to the endpoint devices to start up the system.

    picture4

  5. Widget settings are established to display the data.

    picture5

In addition to greenhouse Cultivation, this recipe can be used in the following environments.

OFFICE

Schools

Research shows that elevated concentrations of CO2 in classrooms is related to drowsiness during lessons. CO2 concentration management is important for maintaining an environment in which students can concentrate on their studies.

COCKPIT

Airplane cockpits

The difficulty of maintaining air circulation in a cockpit makes adjustment of CO2 levels a critical issue. amnimo's amnimo sense recipe solves this issue.